Electromagnetic pulse valve dedusting bag dedusting skeleton pulse valve diaphragm pulse valve coil pulse controller dedusting control cabinet star discharger screw conveyor dedusting flower plate.
Description: The Electromagnetic pulse valve is the “switch” of the blowing air path of the dust cleaning system of the pulse bag filter, and the diaphragm in the valve body is the key to its normal operation. The pulse controller controls the diaphragm vibration in the valve body to inject the pulse “impulse” into the street for dust cleaning. The area of the diaphragm rear control is larger than the area of the front control, and the pressure force is large. Place the diaphragm in a critical position.
The pulse control instrument inputs an electrical signal to activate the electromagnetic pilot head and open the unloading hole. The pressure gas of the diaphragm rear control is discharged. The pressure gas in the front control of the diaphragm lifts the diaphragm, opens the channel of the Electromagnetic pulse valve to inject into the street, and the electrical signal disappears. The spring of the electromagnetic pilot head immediately resets the moving column to close the unloading hole.
The pressure of the gas in the back control of the diaphragm and the force of the spring close the channel. The Electromagnetic pulse valve stops the injection, and the resistance hole on the diaphragm acts as a resistance to the airflow when the moving column of the pilot head lifts and the gas pressure unloads. When the unloading is closed, Fill the pressure gas into the rear chamber, close the channel of the diaphragm, and stop blowing.
The diaphragm divides the Electromagnetic pulse valve into the front and rear air chambers. When the compressed air is connected, the compressed air enters the rear air chamber through the orifice. At this time, the pressure of the rear air chamber pushes the diaphragm assembly close to the output port of the valve, and the Electromagnetic pulse valve is in the “closed” state. The electrical signal of the diaphragm of the pulse solenoid valve makes the armature of the Electromagnetic pulse valve move backward, the vent hole of the rear air chamber opens, the rear air chamber loses pressure, the diaphragm assembly moves backward, compressed air is injected through the output port of the valve, and the Electromagnetic pulse valve is in the “open” state.
Pulse electromagnetic valve (also known as diaphragm valve) is the compressed air “switch” of the pulse bag filter’s blue ash injection system. Controlled by the output signal of the pulse blowing control instrument, pressure is applied to the filter bag to maintain the negative force of the dust collector within the set range, ensuring the processing capacity and dust collection efficiency of the dust collector.
DMF-Z-40 Electromagnetic pulse valve is a right angle valve, and the included angle between its inlet and outlet is 90 °, which is suitable for the installation and connection of the air bag and the jet pipe of the precipitator. The airflow is unobstructed and can provide a satisfactory pulse of ash cleaning gas.
The diaphragm divides the Electromagnetic pulse valve into the front and rear air chambers. When the compressed air is connected, the compressed air enters the rear air chamber through the orifice. At this time, the pressure of the rear air chamber pushes the diaphragm assembly close to the output port of the valve, and the Electromagnetic pulse valve is in the “closed” state.
Pulse electromagnetic valve (also known as diaphragm valve) is the compressed air “switch” of the pulse bag filter’s blue ash injection system. Under the control of the output signal of the pulse blowing control instrument, I have gained a stable understanding of the filter bag lime method.